Static Call Graph for image C:\Keil4\ARM\Boards\Milandr\MCU_1986VE92U\MT12864_Bitmap\MT12864.axf



#<CALLGRAPH># ARM Linker, 4.1 [Build 894]: Last Updated: Wed Oct 28 13:19:12 2015

Maximum Stack Usage = 96 bytes + Unknown(Functions without stacksize, Cycles, Untraceable Function Pointers)

Call chain for Maximum Stack Depth:

__rt_entry_main ⇒ main ⇒ GLCD_Bitmap ⇒ GLCD_PutPixel ⇒ LCD_write_data ⇒ LCD_wait_busy ⇒ LCD_read_status

Functions with no stack information

Mutually Recursive functions

  • NMI_Handler   ⇒   NMI_Handler
  • HardFault_Handler   ⇒   HardFault_Handler
  • MemManage_Handler   ⇒   MemManage_Handler
  • BusFault_Handler   ⇒   BusFault_Handler
  • UsageFault_Handler   ⇒   UsageFault_Handler
  • SVC_Handler   ⇒   SVC_Handler
  • DebugMon_Handler   ⇒   DebugMon_Handler
  • PendSV_Handler   ⇒   PendSV_Handler
  • SysTick_Handler   ⇒   SysTick_Handler
  • ADC_IRQHandler   ⇒   ADC_IRQHandler

    Function Pointers

    Global Symbols

    __main (Thumb, 8 bytes, Stack size 0 bytes, __main.o(!!!main))

    [Calls]

    __scatterload (Thumb, 0 bytes, Stack size unknown bytes, __scatter.o(!!!scatter))

    [Called By]

    __scatterload_rt2 (Thumb, 44 bytes, Stack size unknown bytes, __scatter.o(!!!scatter), UNUSED)

    [Calls]

    __scatterload_rt2_thumb_only (Thumb, 0 bytes, Stack size unknown bytes, __scatter.o(!!!scatter), UNUSED)

    __scatterload_null (Thumb, 0 bytes, Stack size unknown bytes, __scatter.o(!!!scatter), UNUSED)

    __decompress (Thumb, 100 bytes, Stack size unknown bytes, __dclz77c.o(!!dclz77c), UNUSED)

    __decompress2 (Thumb, 0 bytes, Stack size unknown bytes, __dclz77c.o(!!dclz77c), UNUSED)

    __scatterload_zeroinit (Thumb, 28 bytes, Stack size unknown bytes, __scatter_zi.o(!!handler_zi), UNUSED)

    __rt_lib_init (Thumb, 0 bytes, Stack size unknown bytes, libinit.o(.ARM.Collect$$libinit$$00000000))

    [Stack]


    [Calls]
    [Called By]

    __rt_lib_init_alloca_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$0000002A))

    __rt_lib_init_argv_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$00000028))

    __rt_lib_init_atexit_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$00000017))

    __rt_lib_init_clock_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$0000001D))

    __rt_lib_init_cpp_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$0000002E))

    __rt_lib_init_exceptions_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$0000002C))

    __rt_lib_init_fp_trap_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$0000001B))

    __rt_lib_init_getenv_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$0000001F))

    __rt_lib_init_heap_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$00000006))

    __rt_lib_init_lc_collate_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$0000000D))

    __rt_lib_init_lc_ctype_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$0000000F))

    __rt_lib_init_lc_monetary_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$00000011))

    __rt_lib_init_lc_numeric_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$00000013))

    __rt_lib_init_lc_time_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$00000015))

    __rt_lib_init_rand_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$0000000A))

    __rt_lib_init_return (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$0000002F))

    __rt_lib_init_signal_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$00000019))

    __rt_lib_init_stdio_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$00000021))

    __rt_lib_init_user_alloc_1 (Thumb, 0 bytes, Stack size unknown bytes, libinit2.o(.ARM.Collect$$libinit$$00000008))

    __rt_lib_shutdown (Thumb, 0 bytes, Stack size unknown bytes, libshutdown.o(.ARM.Collect$$libshutdown$$00000000))

    [Called By]

    __rt_lib_shutdown_fp_trap_1 (Thumb, 0 bytes, Stack size unknown bytes, libshutdown2.o(.ARM.Collect$$libshutdown$$00000006))

    __rt_lib_shutdown_heap_1 (Thumb, 0 bytes, Stack size unknown bytes, libshutdown2.o(.ARM.Collect$$libshutdown$$0000000E))

    __rt_lib_shutdown_return (Thumb, 0 bytes, Stack size unknown bytes, libshutdown2.o(.ARM.Collect$$libshutdown$$0000000F))

    __rt_lib_shutdown_signal_1 (Thumb, 0 bytes, Stack size unknown bytes, libshutdown2.o(.ARM.Collect$$libshutdown$$00000009))

    __rt_lib_shutdown_stdio_1 (Thumb, 0 bytes, Stack size unknown bytes, libshutdown2.o(.ARM.Collect$$libshutdown$$00000003))

    __rt_lib_shutdown_user_alloc_1 (Thumb, 0 bytes, Stack size unknown bytes, libshutdown2.o(.ARM.Collect$$libshutdown$$0000000B))

    __rt_entry (Thumb, 0 bytes, Stack size unknown bytes, rtentry.o(.ARM.Collect$$rtentry$$00000000))

    [Called By]

    __rt_entry_presh_1 (Thumb, 0 bytes, Stack size unknown bytes, rtentry2.o(.ARM.Collect$$rtentry$$00000002))

    __rt_entry_sh (Thumb, 0 bytes, Stack size unknown bytes, rtentry4.o(.ARM.Collect$$rtentry$$00000004))

    [Stack]


    [Calls]

    __rt_entry_li (Thumb, 0 bytes, Stack size unknown bytes, rtentry2.o(.ARM.Collect$$rtentry$$0000000A))

    [Stack]


    [Calls]

    __rt_entry_postsh_1 (Thumb, 0 bytes, Stack size unknown bytes, rtentry2.o(.ARM.Collect$$rtentry$$00000009))

    __rt_entry_main (Thumb, 0 bytes, Stack size unknown bytes, rtentry2.o(.ARM.Collect$$rtentry$$0000000D))

    [Stack]


    [Calls]

    __rt_entry_postli_1 (Thumb, 0 bytes, Stack size unknown bytes, rtentry2.o(.ARM.Collect$$rtentry$$0000000C))

    __rt_exit (Thumb, 0 bytes, Stack size unknown bytes, rtexit.o(.ARM.Collect$$rtexit$$00000000))

    [Called By]

    __rt_exit_ls (Thumb, 0 bytes, Stack size unknown bytes, rtexit2.o(.ARM.Collect$$rtexit$$00000003))

    [Calls]

    __rt_exit_prels_1 (Thumb, 0 bytes, Stack size unknown bytes, rtexit2.o(.ARM.Collect$$rtexit$$00000002))

    __rt_exit_exit (Thumb, 0 bytes, Stack size unknown bytes, rtexit2.o(.ARM.Collect$$rtexit$$00000004))

    [Calls]

    Reset_Handler (Thumb, 8 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    NMI_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    HardFault_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    MemManage_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    BusFault_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    UsageFault_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    SVC_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    DebugMon_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    PendSV_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    SysTick_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    ADC_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    BACKUP_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    CAN1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    CAN2_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    COMPARATOR_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    DMA_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    EXT_INT1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    EXT_INT2_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    EXT_INT3_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    EXT_INT4_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    I2C_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    POWER_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    SSP1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    SSP2_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    Timer1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    Timer2_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    Timer3_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    UART1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    UART2_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    USB_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    WWDG_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_mdr32f9x.o(.text))
    [Address Reference Count : 1]

    __user_initial_stackheap (Thumb, 0 bytes, Stack size unknown bytes, startup_mdr32f9x.o(.text))

    [Called By]

    SystemCoreClockUpdate (Thumb, 148 bytes, Stack size 12 bytes, system_mdr32f9x.o(.text))

    [Stack]


    [Called By]

    SystemInit (Thumb, 86 bytes, Stack size 4 bytes, system_mdr32f9x.o(.text))

    [Stack]


    [Calls]
    [Address Reference Count : 1]

    frq_init (Thumb, 70 bytes, Stack size 8 bytes, main.o(.text))

    [Stack]


    [Calls]
    [Called By]

    io_init (Thumb, 50 bytes, Stack size 0 bytes, main.o(.text), UNUSED)

    main (Thumb, 38 bytes, Stack size 8 bytes, main.o(.text))

    [Stack]


    [Calls]
    [Called By]

    GLCD_Init (Thumb, 300 bytes, Stack size 8 bytes, glcd_mt12864.o(.text))

    [Stack]


    [Calls]
    [Called By]

    GLCD_Clear (Thumb, 234 bytes, Stack size 16 bytes, glcd_mt12864.o(.text))

    [Stack]


    [Calls]
    [Called By]

    GLCD_PutPixel (Thumb, 174 bytes, Stack size 24 bytes, glcd_mt12864.o(.text))

    [Stack]


    [Calls]
    [Called By]

    GLCD_SetTextColor (Thumb, 6 bytes, Stack size 0 bytes, glcd_mt12864.o(.text), UNUSED)

    GLCD_SetBackColor (Thumb, 6 bytes, Stack size 0 bytes, glcd_mt12864.o(.text), UNUSED)

    GLCD_DrawChar (Thumb, 2418 bytes, Stack size 56 bytes, glcd_mt12864.o(.text), UNUSED)

    [Calls]


    [Called By]

    GLCD_DisplayChar (Thumb, 154 bytes, Stack size 24 bytes, glcd_mt12864.o(.text), UNUSED)

    [Calls]


    [Called By]

    GLCD_DisplayString (Thumb, 40 bytes, Stack size 24 bytes, glcd_mt12864.o(.text), UNUSED)

    [Calls]

    GLCD_ClearLn (Thumb, 1438 bytes, Stack size 32 bytes, glcd_mt12864.o(.text), UNUSED)

    [Calls]

    GLCD_Bargraph (Thumb, 180 bytes, Stack size 40 bytes, glcd_mt12864.o(.text), UNUSED)

    [Calls]

    GLCD_Bitmap (Thumb, 108 bytes, Stack size 40 bytes, glcd_mt12864.o(.text))

    [Stack]


    [Calls]
    [Called By]

    GLCD_ScrollVertical (Thumb, 964 bytes, Stack size 96 bytes, glcd_mt12864.o(.text), UNUSED)

    [Calls]

    GLCD_WrCmd (Thumb, 12 bytes, Stack size 8 bytes, glcd_mt12864.o(.text), UNUSED)

    [Calls]

    __use_two_region_memory (Thumb, 2 bytes, Stack size 0 bytes, heapauxi.o(.text), UNUSED)

    __rt_heap_escrow$2region (Thumb, 2 bytes, Stack size 0 bytes, heapauxi.o(.text), UNUSED)

    __rt_heap_expand$2region (Thumb, 2 bytes, Stack size 0 bytes, heapauxi.o(.text), UNUSED)

    __user_setup_stackheap (Thumb, 74 bytes, Stack size 8 bytes, sys_stackheap_outer.o(.text))

    [Stack]


    [Calls]
    [Called By]

    exit (Thumb, 12 bytes, Stack size 0 bytes, exit.o(.text))

    [Calls]


    [Called By]

    __user_libspace (Thumb, 8 bytes, Stack size 0 bytes, libspace.o(.text), UNUSED)

    __user_perproc_libspace (Thumb, 0 bytes, Stack size 0 bytes, libspace.o(.text))

    [Called By]

    __user_perthread_libspace (Thumb, 0 bytes, Stack size 0 bytes, libspace.o(.text), UNUSED)

    __rt_fp_status_addr (Thumb, 8 bytes, Stack size 0 bytes, rt_fp_status_addr_intlibspace.o(.text))

    [Called By]

    _sys_exit (Thumb, 8 bytes, Stack size 0 bytes, sys_exit.o(.text))

    [Called By]

    __I$use$semihosting (Thumb, 0 bytes, Stack size 0 bytes, use_no_semi.o(.text), UNUSED)

    __use_no_semihosting_swi (Thumb, 2 bytes, Stack size 0 bytes, use_no_semi.o(.text), UNUSED)

    __semihosting_library_function (Thumb, 0 bytes, Stack size 8 bytes, indicate_semi.o(.text), UNUSED)

    _fp_init (Thumb, 14 bytes, Stack size 8 bytes, fpinit.o(x$fpl$fpinit))

    [Stack]


    [Calls]
    [Called By]

    __fplib_config_pureend_doubles (Thumb, 0 bytes, Stack size unknown bytes, fpinit.o(x$fpl$fpinit), UNUSED)

    Local Symbols

    delay (Thumb, 12 bytes, Stack size 0 bytes, glcd_mt12864.o(.text))

    [Called By]

    LCD_read_status (Thumb, 136 bytes, Stack size 8 bytes, glcd_mt12864.o(.text))

    [Stack]


    [Calls]
    [Called By]

    LCD_wait_busy (Thumb, 20 bytes, Stack size 8 bytes, glcd_mt12864.o(.text))

    [Stack]


    [Calls]
    [Called By]

    LCD_read_data (Thumb, 138 bytes, Stack size 8 bytes, glcd_mt12864.o(.text))

    [Stack]


    [Calls]
    [Called By]

    LCD_write (Thumb, 132 bytes, Stack size 8 bytes, glcd_mt12864.o(.text))

    [Stack]


    [Calls]
    [Called By]

    LCD_write_cmd (Thumb, 28 bytes, Stack size 8 bytes, glcd_mt12864.o(.text))

    [Stack]


    [Calls]
    [Called By]

    LCD_write_data (Thumb, 28 bytes, Stack size 8 bytes, glcd_mt12864.o(.text))

    [Stack]


    [Calls]
    [Called By]

    Undefined Global Symbols