Static Call Graph for image E:\Proekts\Pr_LPC1700\Mcb_1700_Keil\zwukeff\zwukeff.axf



#<CALLGRAPH># ARM Linker, 4.1 [Build 894]: Last Updated: Mon Apr 02 12:55:23 2012

Maximum Stack Usage = 8 bytes + Unknown(Cycles, Untraceable Function Pointers)

Call chain for Maximum Stack Depth:

SysTick_Handler

Mutually Recursive functions

  • NMI_Handler   ⇒   NMI_Handler
  • HardFault_Handler   ⇒   HardFault_Handler
  • MemManage_Handler   ⇒   MemManage_Handler
  • BusFault_Handler   ⇒   BusFault_Handler
  • UsageFault_Handler   ⇒   UsageFault_Handler
  • SVC_Handler   ⇒   SVC_Handler
  • DebugMon_Handler   ⇒   DebugMon_Handler
  • PendSV_Handler   ⇒   PendSV_Handler
  • BOD_IRQHandler   ⇒   BOD_IRQHandler

    Function Pointers

    Global Symbols

    __main (Thumb, 0 bytes, Stack size unknown bytes, entry.o(.ARM.Collect$$$$00000000))
    [Address Reference Count : 1]

    _main_stk (Thumb, 0 bytes, Stack size unknown bytes, entry2.o(.ARM.Collect$$$$00000001))

    _main_scatterload (Thumb, 0 bytes, Stack size unknown bytes, entry5.o(.ARM.Collect$$$$00000004))

    [Calls]

    __main_after_scatterload (Thumb, 0 bytes, Stack size unknown bytes, entry5.o(.ARM.Collect$$$$00000004))

    [Called By]

    _main_clock (Thumb, 0 bytes, Stack size unknown bytes, entry7b.o(.ARM.Collect$$$$00000008))

    _main_init (Thumb, 0 bytes, Stack size unknown bytes, entry8.o(.ARM.Collect$$$$00000009))

    Reset_Handler (Thumb, 8 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    NMI_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    HardFault_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    MemManage_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    BusFault_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    UsageFault_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    SVC_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    DebugMon_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    PendSV_Handler (Thumb, 2 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    BOD_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))

    [Calls]


    [Called By]
    [Address Reference Count : 1]

    CANActivity_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    CAN_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    DMA_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    EINT0_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    EINT1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    EINT2_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    EINT3_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    ENET_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    I2C0_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    I2C1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    I2C2_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    I2S_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    MCPWM_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    PLL0_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    PLL1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    PWM1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    QEI_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    RIT_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    RTC_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    SPI_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    SSP0_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    SSP1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    TIMER0_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    TIMER1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    TIMER2_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    TIMER3_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    UART0_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    UART1_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    UART2_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    UART3_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    USBActivity_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    USB_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    WDT_IRQHandler (Thumb, 0 bytes, Stack size 0 bytes, startup_lpc17xx.o(.text))
    [Address Reference Count : 1]

    ADC_Init (Thumb, 100 bytes, Stack size 0 bytes, adc.o(.text))

    [Called By]

    ADC_StartCnv (Thumb, 24 bytes, Stack size 0 bytes, adc.o(.text))

    [Called By]

    ADC_StopCnv (Thumb, 14 bytes, Stack size 0 bytes, adc.o(.text), UNUSED)

    ADC_GetCnv (Thumb, 6 bytes, Stack size 0 bytes, adc.o(.text), UNUSED)

    ADC_IRQHandler (Thumb, 22 bytes, Stack size 0 bytes, adc.o(.text))
    [Address Reference Count : 1]

    DAC_Init (Thumb, 44 bytes, Stack size 0 bytes, dac.o(.text))

    [Called By]

    DAC_StartCnv (Thumb, 10 bytes, Stack size 0 bytes, dac.o(.text))

    [Called By]

    SysTick_Handler (Thumb, 94 bytes, Stack size 8 bytes, irq.o(.text))

    [Stack]


    [Calls]
    [Address Reference Count : 1]

    KNOP_Init (Thumb, 14 bytes, Stack size 0 bytes, knop.o(.text))

    [Called By]

    OPR_kn0 (Thumb, 62 bytes, Stack size 0 bytes, knop.o(.text))

    [Called By]

    __aeabi_llsl (Thumb, 30 bytes, Stack size 0 bytes, llshl.o(.text), UNUSED)

    [Called By]

    _ll_shift_l (Thumb, 0 bytes, Stack size 0 bytes, llshl.o(.text), UNUSED)

    __scatterload_null (Thumb, 2 bytes, Stack size unknown bytes, handlers.o(i.__scatterload_null), UNUSED)

    LED_Init (Thumb, 38 bytes, Stack size 0 bytes, led.o(.text))

    [Called By]

    LED_On (Thumb, 40 bytes, Stack size 0 bytes, led.o(.text))

    [Called By]

    LED_Off (Thumb, 40 bytes, Stack size 0 bytes, led.o(.text))

    [Called By]

    LED_Out (Thumb, 38 bytes, Stack size 8 bytes, led.o(.text), UNUSED)

    [Calls]

    main (Thumb, 690 bytes, Stack size 0 bytes, main.o(.text))

    [Calls]


    [Address Reference Count : 1]

    SystemCoreClockUpdate (Thumb, 426 bytes, Stack size 32 bytes, system_lpc17xx.o(.text), UNUSED)

    [Calls]

    SystemInit (Thumb, 282 bytes, Stack size 0 bytes, system_lpc17xx.o(.text))
    [Address Reference Count : 1]

    __aeabi_uldivmod (Thumb, 98 bytes, Stack size 40 bytes, uldiv.o(.text), UNUSED)

    [Calls]


    [Called By]

    __aeabi_llsr (Thumb, 32 bytes, Stack size 0 bytes, llushr.o(.text), UNUSED)

    [Called By]

    _ll_ushift_r (Thumb, 0 bytes, Stack size 0 bytes, llushr.o(.text), UNUSED)

    __scatterload (Thumb, 28 bytes, Stack size 0 bytes, init.o(.text))

    [Calls]


    [Called By]

    __scatterload_rt2 (Thumb, 0 bytes, Stack size 0 bytes, init.o(.text), UNUSED)

    __scatterload_copy (Thumb, 14 bytes, Stack size unknown bytes, handlers.o(i.__scatterload_copy), UNUSED)

    __scatterload_zeroinit (Thumb, 14 bytes, Stack size unknown bytes, handlers.o(i.__scatterload_zeroinit), UNUSED)

    Local Symbols

    Undefined Global Symbols