Pin Messages
| Report Title | Pin Report |
| Design File | J:\Proekts_GoWin\Tang_Nano_9\Proba_IP\fpga_project\impl\gwsynthesis\fpga_project.vg |
| Physical Constraints File | J:\Proekts_GoWin\Tang_Nano_9\Proba_IP\fpga_project\src\FPGA_constr.cst |
| Timing Constraints File | --- |
| Version | V1.9.8.08 |
| Part Number | GW1NR-LV9QN88PC6/I5 |
| Device | GW1NR-9C |
| Created Time | Thu Jun 15 13:25:03 2023 |
| Legal Announcement | Copyright (C)2014-2022 Gowin Semiconductor Corporation. All rights reserved. |
Pin Details
Pinout by Port Name:
| Port Name | Diff Pair | Loc./Bank | Constraint | Dir. | Site | IO Type | Drive | Pull Mode | PCI Clamp | Hysteresis | Open Drain | Slew Rate | Vref | Single Resistor | Diff Resistor | BankVccio |
| sys_clk | 52/1 | Y | in | IOR17[A] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 | |
| nrst | 4/3 | Y | in | IOL5[A] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 | |
| Input_upr_ind_LCD | 85/3 | Y | in | IOT8[B] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 | |
| RST_JTAG_Soft | 51/1 | Y | in | IOR17[B] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 | |
| UART0RXD_i | 37/2 | Y | in | IOB31[A] | LVCMOS33 | NA | NONE | NA | NONE | NA | NA | NA | NA | NA | 3.3 | |
| buzzer | 42/2 | Y | out | IOB41[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| dat[0] | 25/2 | Y | out | IOB8[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| dat[1] | 26/2 | Y | out | IOB8[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| dat[2] | 27/2 | Y | out | IOB11[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| dat[3] | 28/2 | Y | out | IOB11[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| dat[4] | 29/2 | Y | out | IOB13[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| dat[5] | 30/2 | Y | out | IOB13[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| dat[6] | 33/2 | Y | out | IOB23[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| dat[7] | 34/2 | Y | out | IOB23[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| e | 40/2 | Y | out | IOB33[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| rs | 41/2 | Y | out | IOB41[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| rw | 35/2 | Y | out | IOB29[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| UART0TXD_o | 38/2 | Y | out | IOB31[B] | LVCMOS33 | 8 | NONE | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| button_0 | 3/3 | N | io | IOT2[A] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 | |
| led_0 | 10/3 | Y | io | IOL15[A] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 | |
| led_1 | 11/3 | Y | io | IOL16[B] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 | |
| led_2 | 13/3 | Y | io | IOL21[B] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 | |
| led_3 | 14/3 | Y | io | IOL22[B] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 | |
| led_4 | 15/3 | Y | io | IOL25[B] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 | |
| led_5 | 16/3 | Y | io | IOL26[B] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 | |
| Output_upr_ind_LCD | 86/3 | Y | io | IOT8[A] | LVCMOS33 | 8 | NONE | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 | |
| TRST_JTAG_Soft | 63/1 | Y | io | IOR5[A] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 | |
| TDI_JTAG_Soft | 48/1 | Y | io | IOR24[B] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 | |
| TMS_JTAG_Soft | 49/1 | Y | io | IOR24[A] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 | |
| TCLK_JTAG_Soft | 31/2 | Y | io | IOB15[A] | LVCMOS33 | NA | DOWN | NA | NONE | NA | NA | NA | NA | NA | 3.3 | |
| RTCK_JTAG_Soft | 32/2 | Y | io | IOB15[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 | |
| TDO_JTAG_Soft | 53/1 | Y | io | IOR15[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | OFF | NA | 3.3 |
All Package Pins:
| Loc./Bank | Signal | Dir. | Site | IO Type | Drive | Pull Mode | PCI Clamp | Hysteresis | Open Drain | Slew Rate | Vref | Single Resistor | Diff Resistor | Bank Vccio |
| 3/3 | button_0 | io | IOT2[A] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 |
| 88/3 | - | in | IOT5[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 87/3 | - | in | IOT6[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 86/3 | Output_upr_ind_LCD | io | IOT8[A] | LVCMOS33 | 8 | NONE | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 |
| 85/3 | Input_upr_ind_LCD | in | IOT8[B] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 |
| 84/3 | - | in | IOT10[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 83/3 | - | in | IOT10[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 82/3 | - | in | IOT11[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 81/3 | - | in | IOT11[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 80/3 | - | in | IOT12[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 79/3 | - | in | IOT12[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 77/1 | - | in | IOT37[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 76/1 | - | in | IOT37[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 75/1 | - | in | IOT38[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 74/1 | - | in | IOT38[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 73/1 | - | in | IOT39[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 72/1 | - | in | IOT39[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 71/1 | - | in | IOT41[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 70/1 | - | in | IOT41[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 69/1 | - | in | IOT42[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 68/1 | - | in | IOT42[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 17/2 | - | in | IOB2[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 18/2 | - | in | IOB2[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 19/2 | - | in | IOB4[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 20/2 | - | in | IOB4[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 25/2 | dat[0] | out | IOB8[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 26/2 | dat[1] | out | IOB8[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 27/2 | dat[2] | out | IOB11[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 28/2 | dat[3] | out | IOB11[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 29/2 | dat[4] | out | IOB13[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 30/2 | dat[5] | out | IOB13[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 31/2 | TCLK_JTAG_Soft | in | IOB15[A] | LVCMOS33 | NA | DOWN | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 32/2 | RTCK_JTAG_Soft | out | IOB15[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 33/2 | dat[6] | out | IOB23[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 34/2 | dat[7] | out | IOB23[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 35/2 | rw | out | IOB29[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 36/2 | - | in | IOB29[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 37/2 | UART0RXD_i | in | IOB31[A] | LVCMOS33 | NA | NONE | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 38/2 | UART0TXD_o | out | IOB31[B] | LVCMOS33 | 8 | NONE | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 39/2 | - | in | IOB33[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 40/2 | e | out | IOB33[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 41/2 | rs | out | IOB41[A] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 42/2 | buzzer | out | IOB41[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 47/2 | - | in | IOB43[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 4/3 | nrst | in | IOL5[A] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 |
| 5/3 | - | in | IOL11[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 6/3 | - | in | IOL11[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 7/3 | - | in | IOL12[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 8/3 | - | out | IOL13[A] | LVCMOS18 | 8 | UP | NA | NA | OFF | FAST | NA | NA | NA | 3.3 |
| 9/3 | - | in | IOL13[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 10/3 | led_0 | io | IOL15[A] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 |
| 11/3 | led_1 | io | IOL16[B] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 |
| 13/3 | led_2 | io | IOL21[B] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 |
| 14/3 | led_3 | io | IOL22[B] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 |
| 15/3 | led_4 | io | IOL25[B] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 |
| 16/3 | led_5 | io | IOL26[B] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 |
| 63/1 | TRST_JTAG_Soft | in | IOR5[A] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 |
| 62/1 | - | in | IOR11[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 61/1 | - | in | IOR11[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 60/1 | - | in | IOR12[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 59/1 | - | in | IOR12[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 57/1 | - | in | IOR13[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 56/1 | - | in | IOR14[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 55/1 | - | in | IOR14[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 54/1 | - | in | IOR15[A] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 53/1 | TDO_JTAG_Soft | out | IOR15[B] | LVCMOS33 | 8 | UP | NA | NA | OFF | FAST | NA | OFF | NA | 3.3 |
| 52/1 | sys_clk | in | IOR17[A] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 |
| 51/1 | RST_JTAG_Soft | in | IOR17[B] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 |
| 50/1 | - | in | IOR22[B] | LVCMOS18 | NA | UP | NA | NONE | NA | NA | NA | NA | NA | 3.3 |
| 49/1 | TMS_JTAG_Soft | io | IOR24[A] | LVCMOS33 | 8 | UP | NA | NONE | OFF | FAST | NA | OFF | NA | 3.3 |
| 48/1 | TDI_JTAG_Soft | in | IOR24[B] | LVCMOS33 | NA | UP | NA | NONE | NA | NA | NA | OFF | NA | 3.3 |